Eaton TPC115-10D-3520 ユーザーズマニュアル
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999
2
RACK MOUNTED
•
19” x 1.72” (1U) x 8.0”
•
Approximate shipping weight: 14 lbs.
(10) NEMA OUTLETS
•
2 unswitched on front and 8 switched
on rear panel. Unswitched outlets are
tied to the SW-II outlet section
on rear panel. Unswitched outlets are
tied to the SW-II outlet section
POWER INPUT
•
Power cable with plug is attached to unit
through the rear panel cable grip
through the rear panel cable grip
(3) INDICATOR LIGHTS
•
Main breaker power “on” and power to
the unswitched outlets
the unswitched outlets
•
Power “on” to the SW-I outlets
•
Power “on” to the SW-II outlets
SPIKE/SURGE SUPPRESSION
•
L-N, L-G, N-G
EMI/RFI FILTERING
•
Common Mode Line to Ground
•
Differential Mode Line to Line
OVERLOAD CIRCUIT PROTECTION
•
Electromagnetic breaker
provides manual on/off switching and
trips in an overload condition
provides manual on/off switching and
trips in an overload condition
LOCAL/OFF/REMOTE SWITCHING
•
Local: Power “on or off” to the switched
outlets
outlets
•
Off: When breaker is “on” but this switch
is in the “off” mode, you will have power
to the unswitched outlets only
is in the “off” mode, you will have power
to the unswitched outlets only
•
Remote: Power “on or off” to the
switched outlets via a remote device
•
Latching remote, on “LT” systems, has
the selection switch wired for
the selection switch wired for
Remote/Off/Remote - There is no local
control
control
MULTIPLE TIME DELAY™ (MTD™)
•
Activated “locally” or “remotely”, SW-I
outlets power up immediately, followed
four seconds later by SW-II outlets
outlets power up immediately, followed
four seconds later by SW-II outlets
which is followed four seconds later by
the sequenced remote I/O port.
the sequenced remote I/O port.
•
Add “/MTD” after part number, i.e.
TPC115-10-A/MTD
TPC115-10-A/MTD
REMOTE I/O PORTS
•
3 front/2 rear
•
Remote on/off and EPO control, EPO
overrides remote and local control
overrides remote and local control
•
Sequence Power Up additional
equipment down line (3rd connector on
front panel)
equipment down line (3rd connector on
front panel)
•
Latching remote feature - (N/C) EPO,
momentary start
momentary start
–
Add “-LT” to the part number when
the MTD feature is not being used
–
Add “/LT” to the part number
when the MTD feature is used
SPECIFICATIONS
TPC115-10-A
TPC115-10-A2
TPC115-10-B
TPC115-10-C
TPC115-10-D
TPC115-10-F
Approvals
UL/cUL
UL/cUL
UL/cUL
UL/cUL
UL/cUL
UL/cUL
Voltage Input/Output (50/60Hz)
120V~
120V~
240V~
120V~
120V~
240V~
Current Input
15A
20A
15A
30A
30A
30A
Current Output
12A
16A
12A
24A
24A
24A
Full Load VA
1440VA
1920VA
2880VA
2880VA
2880VA
5760VA
NEMA Outlets
5-15R
5-20R
6-15R
5-15R
5-20R
6-15R
Circuit Breaker with Kick Guard
15A
20A
15/15A
15/15A
15/15A
(2) 15/15A
EMI/RFI Filter
20A
20A
20A
30A
30A
30A
Multi-Stage Surge Suppression
270V/150V
270V/150V
320V/270V
270V/150V
270V/150V
320V/270V
Power Cord/Length
14/3, 9’
12/3, 9’
14/3, 9’
10/3, 15’
10/3, 15’
10/3, 15’
NEMA Power Input Plug
5-15P
5-20P
N/A
L5-30P
L5-30P
L6-30P
TPC115-10-D Front
TPC115-10-D Rear