KitchenAid 30-Inch 5 Burner Induction Double Oven Convection Range 寸法図

ページ / 1
30" (76 cm) Electric Induction Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KFID500E
Electrical Connection: 
•  This range is equipped with a CSA International Certified Power Cord 
intended to be plugged into a standard 14-50R wall receptacle. Be 
sure the wall receptacle is within reach of range's final location.
A.   35
3
4
" ± 
1
8
" (90.8 cm ± 0.3 cm) cooktop height (minimum) with leveling legs 
screwed all the way in*
B.  Model/serial/rating plates (located behind the control panel)**
C.   47
3
8
" ± 
1
8
" (120.3 cm ± 0.3 cm) overall height (minimum) with leveling legs 
screwed all the way in*
D.   28
1
2
" ± 
1
4
" (72.4 cm ± 0.6 cm) depth with handle
E.   26
1
8
" ± 
1
8
" (66.4 cm ± 0.3 cm)***
F.   29
15
16
" ± 
1
16
" (76.0 cm ± 0.2 cm) width
  *  Range can be raised approximately 1" (2.5 cm) by adjusting 
the leveling legs.
 **  Model/serial/rating plates may be rotated up from behind the 
control panel for viewing from the front of the range.
***  Excludes handle. Dimension given is from wall to front of oven 
door and will vary based on electric outlet receptacle installation.
Because Whirlpool Corporation includes a continues commitment to improve our 
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation 
Instructions packed with product. Specifications subject to change without notice.
Cabinet opening dimensions shown are for:
25" (63.5 cm) countertop depth, 
24" (61 cm) base cabinet depth, 
36" (91.4 cm) countertop height
CABINET OPENING DIMENSIONS
Range Rating*
Specified Rating of Power 
Supply Cord Kit and Circuit 
Protection
120/240 Volts
120/208 Volts
Amp
8.8 - 16.5 KW
7.8 - 12.5 KW
40 or 50**
16.6 - 22.5 KW
12.6 - 18.5 KW
50
 *
 The NEC calculated load is less than the total connected load listed 
on the model/serial/rating plate.
**
 If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. 
For 50-amp rated cord kits, use kits that specify use with a nominal 
1
3
/
8
" (3.5 cm) diameter connection opening.
•  A circuit breaker is recommended.
•  Do not use an extension cord.
B**
A*
F
E***
D
C*
Ref. W10694066A
2/10/15
A
B
C
D
E
F
G
H
I
J
K
A.  18" (45.7 cm) upper cabinet to countertop
B.  13" (33.0 cm) upper cabinet depth
C.  30" (76.2 cm) min. opening width.
D.  For minimum clearance to the top of the 
cooktop, see NOTE.
E.  U.S.A.: 30" (76.2 cm) min. opening width
F.   Cabinet door or hinge should not extend 
into cutout*
G.  1" (3.8 cm) min. from right side cabinet
H.  2" (5.1 cm) min. from floor
I.   7" (17.8 cm) min. from floor
J.  8" (20.3 cm) width
K.  3" (8.9 cm) min. from floor
Proper positioning of outlet shown at left.
*  Nothing located in shaded areas can extend more than 1
1
2
" (3.8 cm) 
from wall or range will not slide all the way back.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet 
is covered by not less than 
1
4
" (0.64 cm) flame retardant millboard 
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) 
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking 