KitchenAid 30-Inch 5-Burner Dual Fuel Convection Slide-In Range with Baking Drawer 寸法図

ページ / 2
30" (76.2 cm) Slide-In Dual Fuel Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KSDB900E
Natural Gas: 
•  This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door has
information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local
gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial/rating plate for use with a different gas 
without consulting the serving gas supplier. See “Gas Conversions” 
section.
Gas Supply Line
•  Provide a gas supply line if 3/4" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
 tape.
•  If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D. (inside diameter),
flexible metal appliance connector may be used for connecting range
to the gas supply line.
•  Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.
A.   1
3
\
16
" (3.0 cm) height from 
cooktop to top of vent
B.   29
7
\
8
" (75.9 cm)
C.  Model/serial/rating plate 
(located behind the oven 
door on the top right-hand 
side of the oven frame)
D.  36" (91.4 cm) height to 
top of cooktop edge with 
leveling legs screwed in all 
the way*
E.   28
5
\
16
" (71.9 cm) max. depth 
from front of console to 
back of range
F.   28
7
\
8
" (73.3 cm) max. depth 
from handle to back of 
range
IMPORTANT: Range must be level after installation. Follow 
the instructions in the “Level Range” section. Using the cooktop 
as a reference for leveling the range is not recommended.
*  Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
Because Whirlpool Corporation includes a continues commitment to improve our 
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation 
Instructions packed with product. Specifications subject to change without notice.
GAS SUPPLY REQUIREMENTS
This range is manufactured with the neutral terminal connected to 
the cabinet. Use a 3-wire UL listed, 40- or 50-amp power supply cord 
(pigtail). See the following Range Rating chart. If local codes do not 
permit ground through the neutral, use a 4-wire power supply cord 
rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
ELECTRICAL REQUIREMENTS
Range Rating*
Specified Rating of Power 
Supply Cord Kit and Circuit 
Protection
120/240 Volts
120/208 Volts
Amp
8.8 - 16.5 KW
7.8 - 12.5 KW
40 or 50**
16.6 - 22.5 KW
12.6 - 18.5 KW
50
*
 The NEC calculated load is less than the total connected load listed
on the model/serial/rating plate.
**
 If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. 
For 50-amp rated cord kits, use kits that specify use with a nominal 
1
3
/
8
" (3.5 cm) diameter connection opening.
•  A circuit breaker is recommended.
B
D
A
F
E
C
Ref. W10665259D
8/10/15
Page 1 of 2