4. Repeat steps 1-3 for the underside of the top of the cabinet.
Wall Venting Under Cabinet
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the 
wall:
1. Make 2 lines by measuring 
³⁄₈" (9.5 mm) and 3⁷⁄₈" (9.8 cm) 
down from underside of cabinet and mark on the centerline 
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline 
on the wall.
Use saber or keyhole saw to cut a rectangular opening in the wall 
for the vent.
3. Lift the range hood up under cabinet and determine final 
location by centering beneath cabinet. Mark on the underside 
of cabinet the location of the 4 keyhole mounting slots on the 
range hood. Set range hood aside on a covered surface.
4. Use 
¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
5. Install the 4 - 4.5 x 13 mm mounting screws in pilot holes. 
Leave about 
¹⁄₄" (6.4 cm) space between screw heads and 
cabinet to slide range hood into place.
For Wall Installations:
1. Determine and mark the centerline on the wall where the 
canopy hood will be installed.
2. Select a mounting height between a minimum of 
24" (61.0 cm) for electric cooking surfaces and 30" (76.2 cm) 
for gas cooking surfaces. The suggested maximum height is 
36" (91.4 cm) above the range to the bottom of the hood. 
Mark a horizontal reference line on the wall.
3. Using 2 or more people, center the hood on the vertical 
centerline, then align the bottom of the hood with the 
horizontal reference line marked on the wall.
4. Mark centers of the fastener locations to the wall. Set range 
hood aside on a covered surface.
IMPORTANT: All screws must be installed into wood. If there 
is no wood to screw into, additional wall framing supports 
may be required.
5. Drill 
³⁄₁₆" (4.8 mm) pilot holes at all locations where screws are 
being installed into wood.
6. Install the 4 - 5 x 45 mm mounting screws. Leave a 
¹⁄₄" (6.4 mm) gap between the wall and the back of the 
screw head to slide range hood into place.
7. Determine and make all necessary cuts in the wall or ceiling 
for the vent system. Install the vent system before installing 
the hood. See “Venting Requirements” section.
A. Keyhole slot
A. Drill pilot hole.
5
¹
/
"
(13.3 cm)
5
¹
/
"
(13.3 cm)
*4
¹⁄₂
"
  (11.4 cm)
*From wall, not cabinet frame
Cabinet cutouts
*
¹⁄₂
" (1.3 cm)
³⁄₈
"
3⁷⁄₈
"
Cabinet
front
(0.9 cm)
(9.8 cm)
5
¹⁄₄
"
(13.3 cm)
Centerline
5
¹⁄₄
"
(13.3 cm)
A
A
¹⁄₄
"
(6.4 mm)
A. Horizontal reference line
B. Vertical centerline
C. Mounting height
D. Cooking surface
A. Keyhole slot
A. Drill pilot hole.
A
C
B
X
D
A
A
¹⁄₄
"
(6.4 mm)