Canon imageFORMULA DR-G1130 マニュアル

ページ / 126
5-9
Chapter 5   Maintenance
The imageFORMULA utility will start. 
3.
Click [Canon DR-XXXX USB], and then click 
"Properties". (XXXX depends on the model in use.) 
The scanner properties will be displayed. 
4.
Click [Reset].
The counter value of the "Roller in use" will be reset. 
5.
Click [OK] to close the scanner properties. 
Removing and Reinstalling the Rollers
Follow the procedure shown below to remove and reinstall 
the rollers when you need to clean or replace the Pickup, 
Feed, or Retard Rollers.
CAUTION
• Turn OFF the power switch, and disconnect the power plug from 
the power outlet when you remove or reinstall the rollers. Leaving 
the power turned ON may result in an electric shock.
• Do not place excessive force on the rollers when removing or 
reinstalling the rollers. Deformation of the rollers may cause feed 
errors.
Pickup Roller
Feed Roller
Retard Roller