HP 636075-001 ユーザーズマニュアル

ページ / 62
NOTE:
NOTE:
NOTE:
NOTE: Bus number - Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the
actual bus assignment number
NOTE:
NOTE:
NOTE:
NOTE: Bus width - Indicates the number of physical electrical lanes running to the connector
NOTE:
NOTE:
NOTE:
NOTE: Only single wide cards are supported
NOTE:
NOTE:
NOTE:
NOTE: The shared network port is only supported in the secondary riser connector
(2) x8 PCI-E Riser
(2) x8 PCI-E Riser
(2) x8 PCI-E Riser
(2) x8 PCI-E Riser
(Optional Secondary)
Expansion
Expansion
Expansion
Expansion
Slots #
Slots #
Slots #
Slots #
Technology
Technology
Technology
Technology
Bus
Bus
Bus
Bus
Width
Width
Width
Width
Connector
Connector
Connector
Connector
Width
Width
Width
Width
Bus Number
Bus Number
Bus Number
Bus Number Form Factor
Form Factor
Form Factor
Form Factor
Notes
Notes
Notes
Notes
4
PCIe Gen2
x8
x16
18
Full
Length/Full
Height
 
5
PCIe Gen2
x8
x16
21
Low Profile
 
NOTE:
NOTE:
NOTE:
NOTE: Bus number - Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the
actual bus assignment number
NOTE:
NOTE:
NOTE:
NOTE: Bus width - Indicates the number of physical electrical lanes running to the connector
NOTE:
NOTE:
NOTE:
NOTE: Only single wide cards are supported
NOTE:
NOTE:
NOTE:
NOTE: The shared network port is only supported in the secondary riser connector
Storage Controller
Storage Controller
Storage Controller
Storage Controller
One of the following
depending on Model
Entry Models:
HP Smart Array P410i/Zero Memory Controller
Base Models:
HP Smart Array P410i/256 MB Controller
HP Smart Array P410i/512MB FBWC Controller
High Performance Models: HP Smart Array P410i/1G FBWC Controller
Available upgrades: 1G FBWC, 512MB FBWC, 256MB, 512MB with BBWC, Battery kit upgrade (for
the 256MB cache), and Smart Array Advanced Pack (SAAP)
NOTE:
NOTE:
NOTE:
NOTE: RAID 6 and 60 requires purchase of HP Smart Array Advanced Pack (516471-B21).
Internal Storage Devices
Internal Storage Devices
Internal Storage Devices
Internal Storage Devices
Diskette Drive
None
Optical Drive
One of the following
depending on Model
None Standard
HP Slim SATA DVD RW Optical Drive (standard on Performance Models)
NOTE: 
NOTE: 
NOTE: 
NOTE: The Optical Drive option is not available when you upgrade with the
additional 8 SFF drive cage, or in the LFF Models.
Hard Drives
None Standard
Hard Drive Bays
Standard (8) small form factor (SFF) hot-plug drive bays to support Serial-
attached SCSI (SAS) and Serial ATA (SATA) drives
Optional second drive cage for additional (8) SFF drive bays (total 16)
Optional cage for (6) Large Form Factor SAS/SATA hard drive bays
Maximum Internal
Maximum Internal
Maximum Internal
Maximum Internal
Storage
Storage
Storage
Storage
Hot Plug SFF SAS
16TB
16 x 1TB (with optional SFF drive cage)
Hot Plug LFF SAS
18TB
6 x 3TB (with optional LFF drive cage)
Hot Plug SFF SAS SSD
12.8TB
16 x 800GB (with optional SFF drive cage)
Hot Plug LFF SATA SSD
2.4TB
6 x 400GB (with optional LFF drive cage)
Hot Plug SFF SATA SSD
6.4TB
16 x 400GB (with optional SFF drive cage)
QuickSpecs
HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)
Standard Features
DA - 13594   North America — Version 31 — November 14, 2011
Page 5