ASUS RS700-E7/RS8 ユーザーズマニュアル

ページ / 188
第五章:BIOS  程序設置
5-36
5.5 服務器管理菜單(Server Mgmt menu)
服務器管理菜單(Server Mgmt menu)顯示服務器管理狀態,以及提供
您更改設置。
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
 Main   Advanced  
Server Mgmt
  Event Logs  Boot  Monitor  Seciruty  Tool  Exit
Wait for BMC response for 
specified timeout In PILOTII, 
BMC starts at the same time 
when BIOS starts during AC 
power ON. It takes arround 
30 seconds to initialize 
Host to BMC interfaces.
  BMC Firmware: 
x.xx
  BMC Detect Timout 
 
   120
  FRB-2 Timer timeout 
 
   [6 minutes]
  FRB-2 Timer Policy 
 
   [Reset]
  O/S Watchdog Timer 
       [Disabled]
  O/S Wtd Timer Timeout 
[10 minutes]
  O/S Wtd Timer Policy 
[Reset]
 System Event Log
 BMC network configuration
→←:
 Select Screen 
↑↓:
  Select Item 
Enter: Select Item 
+/-: Change Opt. 
F1: General Help 
F2: Previous Values
F5: Optimized Defaults 
F10: Save & Exit 
ESC: Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BMC Detect Timout [120]
提供您設置等待 BMC 的秒數。使用 <+> 與 <-> 來調整數值。
FRB-2 Timer timeout [6 minutes]
輸入介於 3 至 6 分鐘的時間,提供給 FRB Timer Expiratin 數值。設置
值有:[3 minutes] [4 minutes] [5 minutes] [6 minutes]
FRB-2 Timer Policy [Reset]
當  FRB2  計時器  exprise,則允許系統將應該如何回報。當  FRB2  計時
器關閉時,則不能使用。設置值有:[Do Nothing] [Reset] [Power Down]
O/S Watchdog Timer [Disabled]
若本項目啟用時,啟動的  BIOS  計時器只能通過操作統載入後的  Intel 
Management 軟件進行關閉。協助確定該操作系統已經完成載入或依照 O/S 
Boot Watchdog TImer Policy 
進行。設置值有:[Enabled] [Disabled]
O/S Wtd Timer Timeout [10 minutes]
本項目提供您設置 O/S Boot Watchdog Timer(啟動關門狗計時器)。
若 O/S Boot Watchdog Timer 為關閉,則無法設置。設置值有:[5 minutes] 
[10 minutes] [15 minutes] [20 minutes]
服務器管理菜單(Server  Mgmt  menu)只當您安裝  ASMB  控制卡至主
板上時才會顯示。