HP ProLiant ML330 G6 504055-051 ユーザーズマニュアル

製品コード
504055-051
ページ / 52
System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions
(H x W x D)
(W/O foot stand)
7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm)
Weight
Weight
Weight
Weight
(approximate)
Maximum:
(All hard drives, power
supplies and processors
installed)
66.14 lb (30 kg)
Minimum:
(One hard drive, power
supply and processor
installed)
35.27 lb (16 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
852 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at
240 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL: 
- Click on the system of interest. Example: ML330 G6
- Follow the instructions of the next screens.
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 460 (750) W (at 100 VAC),
460 (750) W (at 200 VAC)
Maximum Peak Power
460 (750) W (at 100 VAC),
460 (750) W (at 200 VAC)
NOTE:
NOTE:
NOTE:
NOTE: See Power Supply Specifications tables
for complete details on 460W PSU and optional
750W.
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per 1,000 ft (1.0° C
per every 305 m) above seal level to a maximum
of 10,000 ft (3050 m) no direct sustained
sunlight . Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the
type and number of options installed. System
performance may be reduced if operating with a
fan fault or above 86°F (30°C).
Non-Operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
QuickSpecs
HP ProLiant ML330 Generation 6 (G6)
HP ProLiant ML330 Generation 6 (G6)
HP ProLiant ML330 Generation 6 (G6)
HP ProLiant ML330 Generation 6 (G6)
Technical Specifications
DA - 13361   Worldwide — Version 31 — November 23, 2010
Page 49