9-3
Chapter 9   Maintenance
❏ Cleaning the Scanning Glass and 
Rollers
If scanned images contain streaks or scanned documents 
become dirty, the scanning glass and rollers inside the 
scanner may be dirty. Use the procedure below to clean 
them on a regular basis. 
1.
Pull the lock lever toward you and then fully open the 
panel unit. 
 
CAUTION
The open/close movement of the panel unit is linked to the up/
down movement of the document eject tray. Do not press on the 
document eject tray when you open the panel unit. 
 
2.
Use a commercially available air blower to remove 
any dust and paper particles that have accumulated 
inside the scanner. 
3.
Use a clean, dry cloth to wipe any dirt off the 
scanning glass. 
 
Hint
There is one scanning glass for the front side of documents, and 
another for the back side. Wipe both of them clean. 
CAUTION
Do not spray water or detergent directly on the scanner. Doing 
so may damage precision mechanisms, such as the light 
source. 
IMPORTANT
Scratches on the scanning glass may cause streaks on 
scanned images, as well as feeding errors. If there are 
scratches on a scanning glass, contact your local authorized 
Canon dealer. 
Lock lever
Scanning Glass