Olympus VN-6000 入門マニュアル

ページ / 5
-
7
-
-
8
-
Notes:
•  The recorder will stop if you leave it idle for 3 minutes during a menu setup operation, when a 
selected item is not applied.
•  If you press the STOP (
4) button during a menu setup operation, the recorder will stop and 
apply the items that were set to that point.
Other Functions
VCVA indicator
h Recording Modes [HQ SP LP]
The recording mode can be chosen from [HQ] (high quality sound record-
ing), [SP] (standard recording) and [LP] (long-term recording).
In Menu mode selection...[HQ], [SP], [LP]
HQ
SP
LP
VN-6500
VN-6000
Approx. 40 h.
30 min.
Approx. 107 h.
55 min.
Approx. 604 h.
15 min.
VN-5500
VN-5000
Approx. 20 h.
5 min.
Approx. 53 h.
40 min.
Approx. 300 h.
30 min.
Current recording mode
Alarm indicator
h Moving File between Folders
You can move files recorded in folders [%], [&], ['] and [(] to other folders. The moved file is 
added to the end of the destination folder.
Current microphone 
sensitivity
2 Press  the  + or – button to 
select what you would like 
to set up.
•  The selected menu item flashes.
3 Press the 
 or 
0 but-
ton to change the setting.
4 Press the PLAY (`) button 
to confirm the setting.
5 Press  the  STOP  () button to close the 
menu.
h Alarm Playback Function [
I
]:
You can use the alarm playback function to sound the alarm tone for 
5 minutes at the scheduled time. Within this 5 minutes, pressing any 
button other than the HOLD switch starts the recorder to playback the 
preselected file.
In Menu mode selection...[
SET], [On], [OFF]
 
After selecting [
SET], press the PLAY (`) button to set the 
time.
Note:
•  With the alarm playback function, only one file can be played back. Select 
a file for the function before setting the time.
1 Select the file you want to transfer, and press 
the 
PLAY (`) button to play it.
Notes:
•  The destination folder and the number of the moved file appear on the display, and moving is 
completed.
•  If the destination folder is full (100 files), [FULL] appears on the display, and you cannot move the 
file to that folder.
2 While the recorder is during playback mode, 
press and hold the 
DISP/MENU button for 1 
second or longer.
3 Press the 9 or 0 but-
ton to select a destination 
folder.
4 Press  the  PLAY (`) but-
ton.
a  Destination folder
b  Destination number of the file
h Microphone Sensitivity [
F
]
h Using the Variable Control Voice 
Actuator [VCVA]
h System Sounds [BEEP]
Informs a button operation or a wrong operation of the recorder by sound. 
System sounds may be turned off.
In Menu mode selection...[On], [OFF]
Note:
•  If the alarm playback function has been set, the alarm will sound at the 
scheduled time even if the system sounds are disabled.
h Timer Recording [TIMER]:
You can schedule for automatic recording, specifying the start time and 
end time of recording. When the timer-controlled recording completes, 
the setting is released.
In Menu mode selection...[
SET], [On], [OFF]
 
After selecting [
SET], press the PLAY (`) button to set the 
time.
To cancel the timer setting:
For the timer in the menu mode, select [
OFF], and press the 
PLAY (`) button.
When the microphone senses that sound has reached a preset volume, 
the built-in Variable Control Voice Actuator (VCVA) starts recording 
automatically, and stops it when the volume drops. Particularly helpful for 
extended recording, the VCVA not only conserves memory by turning off 
recording during silent periods, but also makes playback more efficient 
and convenient.
In Menu mode selection...[On], [OFF]
Notes:
•  During recording, press the + and  buttons to adjust the VCVA level in 
15 levels.
•  The Record/Play indicator light is lit during recording. When the recorder 
is in Standby mode, the Record/Play indicator light flashes and [VCVA
flashes on the display.
Notes:
•  To view the current setting, select [On], and press the PLAY (
`) button.
•  With this function, you can set only the start and the end time of recording. The current settings of 
the recording mode, microphone sensitivity, VCVA and folder are applied for the settings before 
you set timer-controlled recording.
•  The setting exceeding the remaining recording time is not allowed.
•  You can record at any time even if it is not within the specified recording duration. However, if that 
makes the remaining recording time insufficient for the timer-controlled recording, the recording 
will not complete.
•  If any operation is ongoing, the timer-controlled recording is overridden.
To cancel an alarm playback:
For [I] in the menu mode, select [
OFF] and press the PLAY (`) button.
Notes:
•  Regardless of the selected folder, once the alarm playback is set, it operates every day unless the 
setting is canceled.
•  To view the current setting, select [On], and press the PLAY (
`) button.
•  The alarm tone stops automatically if no button is pressed within 5 minutes after the alarm starts. 
The file is not played back in this case.
•  If the recorder has no recorded file in the selected folder, the alarm playback function is not 
available.
•  Alarm playback occurs every day unless it is set to [OFF].
b
a
Timer indicator
Microphone sensitivity is adjustable to meet your recording needs.
In Menu mode selection...[
E
], [
G
]
E
G
High-sensitivity mode that records 
sounds in all directions.
 Low-sensitivity mode suited for 
dictation.
Notes:
•  To ensure successful recording, make a test recording to select 
appropriate microphone sensitivity before recording.
•  If you select [E], we recommend setting the recording mode to [HQ
to best take advantage of the higher sensitivity.
•  If you select [E], background noise may be high depending on the 
recording conditions.
Notes:
•  The recording time shown above is for one continuous file. The available recording time may be 
shorter than specified if several files are recorded. (Use the remaining time and recorded time 
only as references.)