Netgear WC7520 - ProSafe 20-AP Wireless Controller 参照マニュアル
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Maintaining the Controller
143
ProSafe 20-AP Wireless Controller WC7520
Figure 69.
2.
Enable SNMP and configure the settings as explained in the following table:
3.
Click Apply to save your settings.
Note:
The wireless controller supports Telnet and SSH through the
console port. However, the console port is for debugging under
guidance of NETGEAR technical support only.
guidance of NETGEAR technical support only.
Table 32. SNMP settings
Setting
Description
SNMP
Select this check box to enable SNMP for the wireless controller.
Read-Only Community Name
Enter the community string that allows the SNMP manager to read the
wireless controller’s MIB objects. The default setting is public.
wireless controller’s MIB objects. The default setting is public.
Read-Write Community Name
Enter the community string that allows the SNMP manager to read and
write the wireless controller’s MIB objects. The default setting is private.
write the wireless controller’s MIB objects. The default setting is private.
Trap Community Name
Enter the community name that is associated with the IP address to
receive traps. The default setting is trap.
receive traps. The default setting is trap.
IP Address to Receive Traps
Enter the IP address at which the SNMP manager receives traps sent from
the wireless controller.
the wireless controller.
Trap Port
Enter the port on which the SNMP manager receives traps sent from the
wireless controller. The default setting is port 162.
wireless controller. The default setting is port 162.
SNMP Manager IP
Enter the IP address of the SNMP manager.
Note:
To allow any SNMP manager to access the wireless controller,
keep this field blank.