Netgear WC7600v2 – ProSAFE Wireless Controller ユーザーズマニュアル
Configure the System and Network Settings and Register the Licenses
115
ProSAFE Wireless Controller
To configure the syslog settings for an internal location:
1.
Open a web browser, and in the browser’s address field, type the wireless controller’s IP
address.
address.
By default, the IP address is 192.168.0.250.
The wireless controller’s login window opens.
2.
Enter your user name and password.
3.
Click the Login button.
The wireless controller’s web management interface opens and displays the Summary
page.
page.
4.
Select Configuration > System > Alerts/Logs > Logs/Syslog.
5.
In the Syslog Settings section of the page, configure the settings as described in the
following table.
following table.
Setting
Description
Enable Syslog
Enable the syslog settings using the Enable Syslog check box to forward
system wide logs to an external syslog server or to save to a storage device
such as a USB or SD card connected to the wireless controller. By default, the
syslog settings are disabled.
system wide logs to an external syslog server or to save to a storage device
such as a USB or SD card connected to the wireless controller. By default, the
syslog settings are disabled.
Log Level
From the Log Level menu, select one of the following levels:
•
LOG_LEVEL_CRIT. Critical errors only are logged.
•
LOG_LEVEL_ERR. Noncritical errors and critical errors are logged.
•
LOG_LEVEL_WARN. Warnings, noncritical errors, and critical errors are
logged.
logged.
•
LOG_LEVEL_NOTICE. Notifications, warnings, noncritical errors, and
critical errors are logged.
critical errors are logged.
•
LOG_LEVEL_INFO. Informational messages, notifications, warnings,
noncritical errors, and critical errors are logged.
noncritical errors, and critical errors are logged.
Syslog Location
Select the Internal radio button if you have already mounted a storage device
(see
(see