Configure the System and Network Settings and Register the Licenses 
115
 ProSAFE Wireless Controller
To configure the syslog settings for an internal location:
1. 
Open a web browser, and in the browser’s address field, type the wireless controller’s IP 
address.
By default, the IP address is 192.168.0.250.
The wireless controller’s login window opens.
2. 
Enter your user name and password.
3. 
Click the Login button.
The wireless controller’s web management interface opens and displays the Summary 
page.
4. 
Select Configuration > System > Alerts/Logs > Logs/Syslog
5. 
In the Syslog Settings section of the page, configure the settings as described in the 
following table.
Setting
Description
Enable Syslog
Enable the syslog settings using the Enable Syslog check box to forward 
system wide logs to an external syslog server or to save to a storage device 
such as a USB or SD card connected to the wireless controller. By default, the 
syslog settings are disabled.
Log Level
From the Log Level menu, select one of the following levels:
• 
LOG_LEVEL_CRIT. Critical errors only are logged.
• 
LOG_LEVEL_ERR. Noncritical errors and critical errors are logged.
• 
LOG_LEVEL_WARN. Warnings, noncritical errors, and critical errors are 
logged.
• 
LOG_LEVEL_NOTICE. Notifications, warnings, noncritical errors, and 
critical errors are logged.
• 
LOG_LEVEL_INFO. Informational messages, notifications, warnings, 
noncritical errors, and critical errors are logged.
Syslog Location
Select the Internal radio button if you have already mounted a storage device 
(see