Netgear XCM8810 - 8800 SERIES 10-SLOT CHASSIS SWITCH ユーザーズマニュアル

ページ / 968
76
   
|   
Chapter 3.  Managing the Switch  
NETGEAR 8800 User Manual 
Note:  
If you override automatic power supply management, you may 
reduce the available power and cause one or more I/O modules to 
power down. 
To resume using automatic power supply management on a PSU, use the 
configure power 
supply
 
<ps_num> auto
 command. The setting for each PSU is stored as part of the switch 
configuration.
To display power supply status and power budget information, use the 
show power
 and 
show 
power budget
 commands. 
Displaying Power Supply Information
To display the status of the currently installed power supplies on all switches, use the 
following command:
show power {<ps_num>} {detail} 
On modular switches, the following commands provide additional power supply information.
To view the system power status and the amount of available and required power, use the 
following command:
show power budget 
To display the status of the currently installed power supply controllers on modular switches, 
use the following command:
show power controller {<num>} 
Using the Simple Network Management Protocol
Any network manager program running the Simple Network Management Protocol (SNMP) 
can manage the switch, provided the Management Information Base (MIB) is installed 
correctly on the management station. Each network manager program provides its own user 
interface to the management facilities. 
Note:  
When using a network manager program to create a VLAN, 
NETGEAR does not support the SNMP create and wait operation. 
To create a VLAN with SNMP, use the create and go operation. 
The following sections describe how to get started if you want to use an SNMP manager. It 
assumes you are already familiar with SNMP management. If not, see the following 
publication: