Netgear M6100 – Campus Edge and SMB Core Chassis Switches 管理者ガイド
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Internet
PC 1
PC 2
Layer 2 switch
10.100.5.34
192.168.1.
192.168.1.
192.168.1.252
192.168.1.252
Security Management
359
Managed Switches
Figure 34. Protected ports
CLI: Configure a Protected Port to Isolate Ports on the Switch
1.
Create one VLAN 192 including PC 1 and PC 2.
(Netgear Switch) #vlan database
(Netgear Switch) #vlan 192
(Netgear Switch) #vlan routing 192
(Netgear Switch) #exit
(Netgear Switch) #configure
(Netgear Switch) (Config)#interface 1/0/23
(Netgear Switch) (Interface 1/0/23)#vlan pvid 192
(Netgear Switch) (Interface 1/0/23)#vlan participation include 192
(Netgear Switch) (Interface 1/0/23)#exit
(Netgear Switch) (Config)#interface 1/0/24
(Netgear Switch) (Interface 1/0/24)#vlan pvid 192
(Netgear Switch) (Interface 1/0/24)#vlan participation include 192
(Netgear Switch) (Interface 1/0/24)#exit
(Netgear Switch) (Interface-vlan 192)#interface vlan 192
(Netgear Switch) (Interface-vlan 192)#routing
(Netgear Switch) (Interface-vlan 192)#ip address 192.168.1.254 255.255.255.0
(Netgear Switch) (Interface-vlan 192)#exit