Netgear M6100 – Campus Edge and SMB Core Chassis Switches 管理者ガイド
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
VLANs
64
Managed Switches
-
You configure various VLAN parameters such as membership, tagging, and PVID by
using legacy commands.
using legacy commands.
-
You can enable or disable ingress filtering.
PC1
PC2
Switch
Network
1/0/1 access port
in VLAN 1000
in VLAN 1000
1/0/2 access port
in VLAN 2000
in VLAN 2000
1/0/3 trunk port
that allows
LANs 1000 and 2000
that allows
LANs 1000 and 2000
The following figure shows a configuration with access ports and a trunk port.
Figure 7. Access and trunk ports
CLI: Configure a VLAN Trunk
1.
Create VLAN 1000 and 2000.
(Netgear Switch) #vlan database
(Netgear Switch) (Vlan)#vlan 1000
(Netgear Switch) (Vlan)#vlan 2000
(Netgear Switch) (Vlan)#exit
2.
Configure port 1/0/1 as an access port.
(Netgear Switch) #config
(Netgear Switch) (Config)#interface 1/0/1
(Netgear Switch) (Interface 1/0/1)#switchport mode access
(Netgear Switch) (Interface 1/0/1)#switchport access vlan 1000
(Netgear Switch) (Interface 1/0/1)#exit
(Netgear Switch) (Config)#