Maintenance 
302
S3300 Smart Switch 
1. 
Use IP Address/Hostname to enter the IP address or Hostname of the station you want 
the switch to discover a path. The default value is blank. The IP Address or Hostname 
you enter is not retained across a power cycle.
2. 
Enter the number of Probes Per Hop. The default value is 3. The range is 1 to 10. The 
Probes per Hop you enter is not retained across a power cycle.
3. 
Enter the Maximum TTL for the destination. The default value is 30. The range is 1 to 255. 
The MaxTTL you enter is not retained across a power cycle.
4. 
Enter the Initial TTL to be used. The default value is 1. The range is 1 to 255.The InitTTL 
you enter is not retained across a power cycle.
5. 
Enter the Maximum Failures allowed in the session. The default value is 5. The range is 1 
to 255. The MaxFail you enter is not retained across a power cycle.
6. 
Interval (secs) - Enter the Time between probes in seconds. The default value is 3. The 
range is 1 to 60. The Interval you enter is not retained across a power cycle.
7. 
Enter the UDP Destination Port in probe packets. The default value is 33434. The range is 
1- 65535. The port you enter is not retained across a power cycle.
8. 
Enter the Size of the probe packets. The default value is 0. The range is 0 to 39936. The 
Size you enter is not retained across a power cycle.
9. 
Enter the Source IP address or interface to use when sending the echo request packets. If 
source is not required, select None as the source option. Possible values are:
None
 
  The source address of the ping packet would be the address of the default 
outgoing interface.
IP Address
 
  The source IP address to use when sending the Echo request packets. 
This field is shown when IP Address is selected as the source option.
Interface
 
  The interface to use when sending the Echo request packets. This field is 
shown when Interface is selected as the source option.
Note:
Values configured in the fields above are not saved to the switch. As a 
result, refreshing the page sets these fields to the default values.
10. 
Click APPLY to sends a traceroute request to the specified IP address or hostname. The 
results are displayed below the configurable data in the TraceRoute Results area.
11. 
Click CANCEL to cancel the operation on the screen and reset the data on the screen to the 
latest value of the switch.
Traceroute IPv6
Use this screen to tell the switch to send a TraceRoute request to a specified IPv6 address or 
Hostname. You can use this to discover the paths packets take to a remote destination. Once 
you click the APPLY button, the switch will send a traceroute and the results will be displayed 
below the configurable data. 
If a reply to the traceroute is received, you will see:
1 a:b:c:d:e:f:g 9869 usec 9775 usec 10584 usec