 GS728TS, GS728TPS, GS752TS, and GS752TPS Gigabit Smart Switches
LLDP-MED Port Settings
Use this page to enable LLDP-MED mode on an interface and configure its properties. 
To display this page, click System > LLDP > Advanced > LLDP-MED Port Settings
To configure LLDP-MED settings for a port:
1. 
From the Port field, select the port to configure.
2. 
From the LLDP-MED Status field, enable or disable the LLDP-MED mode for the selected 
interface.
3. 
From the Notification field, specify whether the port should send a topology change 
notification if a device is connected or removed.
4. 
From the Transmit Optional TLVs field, specify whether the port should transmit optional 
type length values (TLVs) in the LLDP PDU frames. If enabled, the following LLDP-MED 
TLVs are transmitted:
•     
MED Capabilities
•     
Network Policy
•     
Location Identification
•     
Extended Power via MDI: PSE
•     
Extended Power via MDI: PD
•     
Inventory
5. 
Click Apply to send the updated configuration to the switch. These changes occur 
immediately and the configuration will be saved.
6. 
Click Cancel to cancel the configuration on the screen and reset the data on the screen to 
the latest value of the switch. 
7. 
Click Refresh to update the screen with the current information.