Netgear M5300-28G3 (GSM7328Sv2h2) - ProSAFE 24+4 Gigabit Ethernet L3 Managed Stackable Switch ソフトウェアガイド

ページ / 764
Configure System Information 
117
 M6100, M5300, and M7100 Series Managed Switches
This sets the threshold level at which a trap is sent if consumed power is greater than the 
threshold power.
10. 
The Power Management mode describes or controls the power management algorithm 
used by the PSE to deliver power to the requesting PDs. 
Select Static to indicate that the power allocated for each port depends on the type of 
power threshold configured on the port. Select Dynamic to indicate that the power 
consumption on each port is measured and calculated in real-time.
11. 
To set the traps, select Enable to activate the PoE traps. 
Select Disable to deactivate the PoE traps. The default setting is enabled.
12. 
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect 
immediately.
The following table describes the PoE Configuration nonconfigurable fields.
Configure PoE Ports
To configure PoE port settings:, 
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
Table 41.  PoE Configuration 
 
Field
Description
Units
The current PoE Unit. You can change the PoE Unit by selecting 
another unit ID listed here. 
Firmware Version 
The version of the PoE controller's FW image. 
Power Status 
Indicates the power status. 
Total Power (Main AC)
The total power provided by the MAIN AC power source.
Total Power (RPS)
Total Power (PD) for GSM5212P 
switches only
The total power provided by the redundant power source.
Power Source
Current source of system power (Main AC or RPS).
Threshold Power 
System can power up one port, if consumed power is less than this 
power. i.e. Consumed power can be between Nominal and Threshold 
Power values. The threshold power value is effected by changing 
System Usage Threshold. 
Consumed Power 
Total amount of a power which is currently being delivered to all ports.