Netgear M4300-48X (XSM4348CS) - Stackable Switches with Full PoE+ Provisioning ソフトウェアガイド
Utility Commands
335
M4200 and M4300 Series ProSAFE Managed Switches
Remote Monitoring Commands
Remote Monitoring (RMON) is a method of collecting a variety of data about network traffic.
RMON supports 64-bit counters (RFC 3273) and High Capacity Alarm Table (RFC 3434).
RMON supports 64-bit counters (RFC 3273) and High Capacity Alarm Table (RFC 3434).
Note:
There is no configuration command for ether stats and high capacity
ether stats. The data source for ether stats and high capacity ether
stats are configured during initialization.rmon alarm
ether stats. The data source for ether stats and high capacity ether
stats are configured during initialization.rmon alarm
rmon alarm
This command sets the RMON alarm entry in the RMON alarm MIB group.
Format
rmon alarm alarm-number variable sample-interval {absolute | delta}
rising-threshold value [rising-event-index] falling-threshold value
[falling-event-index] [startup {rising | falling | rising-falling}] [owner
string]
Mode
Global Config
Parameter
Description
Alarm Index
An index that uniquely identifies an entry in the alarm table. Each entry defines a diagnostic sample
at a particular interval for an object on the device. The range is 1 to 65535.
Alarm Variable
The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1
primitive type of integer.
primitive type of integer.
Alarm Interval
The interval in seconds over which the data is sampled and compared with the rising and falling
thresholds. The range is 1 to 2147483647. The default is 1.
thresholds. The range is 1 to 2147483647. The default is 1.
Alarm Absolute
Value
The value of the statistic during the last sampling period. This object is a read-only, 32-bit signed
value.
value.
Alarm Rising
Threshold
The rising threshold for the sample statistics. The range is 2147483648 to 2147483647. The default
is 1.
is 1.
Alarm Rising Event
Index
The index of the eventEntry that is used when a rising threshold is crossed. The range is 1 to 65535.
The default is 1.
The default is 1.
Alarm Falling
Threshold
The falling threshold for the sample statistics. The range is 2147483648 to 2147483647. The default
is 1.
is 1.
Alarm Falling Event
Index
The index of the eventEntry that is used when a falling threshold is crossed. The range is 1 to 65535.
The default is 2.
The default is 2.
Alarm Startup
Alarm
Alarm
The alarm that may be sent. Possible values are rising, falling or both rising-falling. The default is
rising-falling.
rising-falling.
Alarm Owner
The owner string associated with the alarm entry. The default is monitorAlarm.