Netgear M4300-24X (XSM4324CS) - Stackable Switches with Full PoE+ Provisioning 管理者ガイド
iSCSI
675
Managed Switches
Enable iSCSI Awareness with VLAN Priority Tag
The example is shown as CLI commands and as web interface procedure.
CLI: Enable iSCSI Awareness with VLAN Priority Tag
Use the following commands to enable iSCSI awareness, select VPT, and set VLAN number
and aging time.
and aging time.
Web Interface: Enable iSCSI Awareness with VLAN Priority Tag
1.
Enable iSCSI awareness, select VPT, and set VLAN number and aging time.
a. Select Switching > iSCSI > Basic.
A screen similar to the following displays.
b. Enter the following information:
•
Next to iSCSI Status, select the Enable radio button.
•
Next to QoS Profile, select the VLAN Priority Tag radio button.
•
From the VLAN Priority Tag menu, select 5 (the default value).
•
Next to Remark, select the Enable radio button (the default value).
•
In the iSCSI Aging Time field, enter 10 (the default value).
c. Click Apply to save the settings.
(Netgear Switch) #config
(Netgear Switch) (Config) #iscsi enable
(Netgear Switch) (Config) #iscsi cos vpt 5
(Netgear Switch) (Config) #iscsi aging time 10
(Netgear Switch) (Config) #exit