KitchenAid 30" Wall-Mount Canopy Hood インストールガイド

ページ / 28
8
2. Place the other chimney bracket on the wall so that its lower 
edge is 16
³⁄₁₆" (41.1 cm) from the ceiling or soffit and level.
Align the center notches of the bracket and the centerline. 
Mark the centers of the bracket holes.
3. Drill pilot holes.
If installing into wood, drill 4 - 
³⁄₃₂" (2.4 mm) pilot holes.
If installing into plaster or drywall, drill 4 - 
³⁄₁₆" (4.8 mm) 
pilot holes and insert drywall anchors flush with the wall.
4. Attach each bracket to the wall with 2 - #10 Phillips head 
mounting screws. Tighten screws securely.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent 
system. Install the vent system before installing the range 
hood. See the “Venting Requirements” section.
2. Determine the location where the power supply cable will be 
run through the wall.
NOTE: For wiring flexibility, the terminal box is external to the 
range hood motor. About 24" (61.0 cm) of wire connects the 
terminal box to the range hood motor.
Check that the lower chimney cover will hide the selected 
location.
3. Drill a 1
¹⁄₄" (3.2 cm) hole at this location.
4. Mark and drill the terminal box mounting holes.
5. Pull enough power supply cable through the wall to allow for 
easy connection to the terminal box.
Install Range Hood
1. Use a flat-blade screwdriver and tighten the 2 leveling screws 
located close to the range hood mounting brackets.
2. Use a Phillips screwdriver and remove the terminal box cover. 
Set cover aside.
Vented Installations
Go to Step 6.
Non-vented (recirculating) Installations
3. Install the non-vented (recirculating) conversion kit ordered 
for your range hood.
4. Fit the diverter over the vent motor exhaust outlet and push 
down to seat on outlet. Check that the diverter exhaust 
outlets are parallel with the vent motor sides so that they will 
align with the vent cover openings in the lower chimney.
5. Install the 2 vent extension pieces onto the diverter pushing 
them until they stop.
6. Using 2 or more people, lift the range hood and place the 
mounting hood brackets over the mounting screws. Securely 
tighten the screws.
7. Level the range hood. Adjust the 2 leveling screws (see 
Step 1) as needed.
8. If not previously done, center the wiring hole in the terminal 
box over the hole in the wall, mark the 2 terminal box 
mounting holes. Drill holes as needed for your installation.
A. Leveling screw
 
A
A. Diverter
B. Vent motor
A. Diverter
B. Exhaust extension
A
B
A
B
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.