KitchenAid True Convection Oven Frameless Cooktop Full-Width Cast-Iron Grates Pro Line™ Series gas range 寸法図

ページ / 2
30" Freestanding and Slide-In Gas Range
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KGRS807S
KGRS807X
KGSK901S
KGSS907S
KGSS907X
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526089A
2/13/13
A
B
E
D*
C
F**
Freestanding Range
*Range can be raised approximately 1" (2.5 cm) by adjusting 
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) 
countertop; front of oven door protrudes 1" (2.5 cm) beyond 
24" (61 cm) base cabinet.
A.
" (14.6 cm)
B. 30" (76.2 cm)
C. 41 " (106 cm) overall height 
with leveling legs screwed all 
the way in
D. 36" (91.4 cm) cooktop trim 
height with leveling legs 
screwed all the way in*
E. Model/serial number plate 
(located on the right-hand 
side oven door trim)
F. 27 " (69.2 cm) max. from 
handle to standoff at back 
of range**
B*
D
A
E**
C
F
Slide-in Range
*Range can be raised approximately 1"  (2.5 cm) by adjusting 
the leveling legs.
**
A. 30
" (77.6 cm)
B. 35 " (90.5 cm) height to 
underside of cooktop edge 
with leveling legs screwed 
all the way in*
C. Model/serial number plate 
(located on the right-hand 
side oven door trim)
D 30" (76.2 cm)
F. 23" (58.4 cm) countertop 
notch to rear of cooktop
on models KGRS807XSP and
KGSS907XSP) from handle to
standoff at back of range**
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with Natural
gas or, after proper conversion, for use with LP gas.
● 
This range is factory set for use with Natural gas. See the “Gas
Conversions” section. The model/serial rating plate located behind the
storage drawer on the right-hand side oven frame has information on
the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting the serving gas supplier. See the “Gas Conversions”
section.
Gas Supply Line
● 
Provide a gas supply line of 
³⁄₄" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be 
¹⁄₂" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system.
NOTE:
Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
● 
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, 
¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
● 
¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
● 
Do not kink or damage the flexible metal tubing when moving the
range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to
obtain an in-line connection to the range. The rigid pipe must be level
with the range connection. All strains must be removed from the
supply and fuel lines so range will be level and in line.
● 
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
A
B
C
Page 1 of 2
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be
provided.
ELECTRICAL REQUIREMENTS