KitchenAid 30-Inch 4-Burner Dual Fuel Slide In Range, Architect® Series II インストールガイド

ページ / 44
20
Complete Installation
1. Check that all parts are now installed. If there is an extra part, 
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that range level. See the “Level Range” section.
5. Use a mild solution of liquid household cleaner and warm 
water to remove waxy residue caused by shipping material. 
Dry thoroughly with a soft cloth. For more information, see 
the “Range Care” section of the Use and Care Guide.
6. Read the “Range Use” section in the Use and Care Guide.
7. Plug power cord into appropriate outlet. Slide range into its 
final location. Check that the flexible conduit or power supply 
cord are not bent.
8. Turn on surface burners and oven. See the Use and Care 
Guide for specific instruction on range operation. 
If range does not operate, check the following:
Household fuse is intact and tight, or circuit breaker has not 
tripped.
Range is plugged into an outlet.
Electrical supply is connected.
See the “Troubleshooting” section in the Use and Care Guide.
9. When the range has been on for 5 minutes, check for heat. If 
the range is cold, turn off the range and check that the gas 
supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then 
repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, close it, and 
contact a qualified technician.
If you need Assistance or Service:
Please reference the “Assistance or Service” section of the 
Use and Care Guide or contact the dealer from whom you 
purchased your range.
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas; or from LP gas to 
Natural gas must be done by a qualified installer.
LP Gas Conversion
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 
instructions.
Slide range back so rear range foot is engaged in the 
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 
and engaged.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C