KitchenAid 30" Range Hood with the FIT System 寸法図

ページ / 2
Range Hood – 30" (76.2 cm) and 36" (91.4 cm) 
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
UXT5230BD
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. 
Use copper wire only. A time-delay fuse or circuit breaker and
separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see 
Installation Instructions packed with product. Specifications subject to 
change without notice.
1" 
(2.5 cm)
4¹⁵⁄₁₆" 
(12.5 cm)
6⁹⁄₁₆" (16.7 cm) or
9⁹⁄₁₆" (24.4 cm)
 
29¹⁵⁄₁₆" (76.0 cm)
 
or 
35¹⁵⁄₁₆" (91.0 cm)
18⁵⁄₈" 
(47.3 cm)
 1¹⁄₂
(3.8 cm)
9" 
(22.9 cm)
2" 
(5.1 cm)
1" 
(2.5 cm)
INSTALLATION CLEARANCES 
B
A
C
D
E
  
Venting Methods
Page 1 of 2
UXT5236BD
A.  18" (45.7 cm) minimum distance from electric cooking surface. 
      24" (61.0 cm) minimum distance from gas cooking surface. 
     30" (76.2 cm) suggested maximum above the cooking surface.
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop.
C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm)  
       
    models and 36" (91.4 cm) minimum cabinet width for 
     36" (91.4 cm) models.
D. 12" (30.5 cm) cabinet depth.
E. 36" (91.4 cm) base cabinet height.
NOTES:
Flexible vent is not recommended. Flexible vent creates       
 
both back pressure and air turbulence that greatly reduce    
 performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall. Use 
31/4" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent 
length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with 
a maximum length of 50 ft (15.2 m) for vent system.
A
B
A
B
Top Venting
Wall Venting
A. 7" (17.8 cm) round vent  
 
    through roof 
    (purchased separately).   
       
    3
1/4
" x 10" (8.3 x 25.4 cm) 
    rectangular vent through the  
    roof (purchased separately).
B. Roof cap with damper  
 
    (purchased separately)
A. 7" (17.8 cm) round vent out
     the top and through the wall
     (purchased separately).
     3
1/4
" x 10" (8.3 x 25.4 cm)
     rectangular vent through the
     wall or out the top    
 
     (purchased separately).
B. Wall cap with damper
     (purchased separately)
  
Example vent system
Wall cap
 
 
 
 
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
1 - 90° elbow  
 
 
 
= 5.0 ft (1.5 m)
1 - wall cap  
 
 
 
= 0.0 ft (0.0 m) 
8 ft (2.4 m) straight  
 
 
= 8.0 ft (2.4 m) 
System length    
 
 
= 13.0 ft (3.9 m 
Maximum Recommended Length) 
  7” (17.8 cm) Round Vent  
 
= 50 ft (15.2 m)
 31/4" x 10" (8.3 x 25.4 cm)  
 
= 35 ft (10.7 m)
  Rectangular Vent
W10646405-D-UN 