Electrical Requirements
Observe all governing codes and ordinances. 
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 (latest 
edition), or CSA Standards C22.1-94, Canadian Electrical Code, 
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 
and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 
required.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial rating plate. 
The model/serial plate is located behind the filter on the rear 
wall of the hood.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
INSTALLATION INSTRUCTIONS
Venting Options
General venting installation
For vented installations: 
Make necessary cuts in the wall for vent fittings. 
IMPORTANT: Make sure the vent system is installed before 
installing range hood.
Recirculating installations:
A vent system (not provided) that directs the recirculated air back 
into the room either through the soffit or through the cabinet top 
is required. Use Recirculation Kit Part Number 4396565. For 
ordering information, see “Assistance or Service.”
IMPORTANT: If venting through the cabinet top, do not 
terminate the exhaust into dead air space such as an attic or 
enclosed soffit.
When venting through the soffit, assemble the vent system you 
will use over the exhaust collar, but do not attach the vent system 
yet.
NOTE: The vent system can exhaust out the front of the soffit or 
be rotated to exhaust out the side or end of the soffit.
Venting through the soffit
1. Assemble the vent system you will use over the exhaust 
collar, but do not attach the vent system yet.
NOTE: The vent system can exhaust out the front of the soffit 
or be rotated to exhaust out the side or end of the soffit.
2. Measure distance “A” (from top of hood to centerline of 
6" [15.2 cm] round vent). Mark the distance “A” on soffit.
3. Mark and cut a 6" (15.2 cm) round vent opening.
Venting through cabinet top
1. Mark the location where vent cover will be installed in the 
cabinet top and cut a 6" (15.2 cm) round vent opening for the 
vent cover.
IMPORTANT: Do not terminate exhaust into a dead air space 
such as an attic or enclosed soffit.
A. Vent system
B. Vent cover
C. Cabinet top
D. Ceiling or soffit
E. Hood
A
A
B
C
D
E