KitchenAid 30" Retractable Downdraft System with Interior Blower Motor 使用とお手入れ

ページ / 44
10
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
Rectangular
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
90° elbow
5.0 ft 
(1.5 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
flat elbow
12.0 ft 
(3.7 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
wall cap
0.0 ft 
(0.0 m)
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft 
(0.8 m)
90° elbow
5.0 ft 
(1.5 m)
6" (15.2 cm) wall cap
0.0 ft 
(0.0 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) transition
4.5 ft 
(1.4 m)
6" (15.2 cm) to 3
1
/
4
" x 10" 
(8.3 cm x 25.4 cm) transition
1 ft 
(0.3 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) 90° elbow 
transition
5.0 ft 
(1.5 m)
6" (15.2 cm) to 3
1
/
4
" x 10" 
(8.3 cm x 25.4 cm) 90° elbow 
transition
5.0 ft 
(1.5 m)
Example Vent System
The following example falls within the maximum vent length  
of 35 ft (8.9 m).
2 - 90° elbow
= 10.0 ft (3 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Transition
= 4.5 ft (1.4 m)
Length of 6" (15.2 cm) or 3
1
/
4
" x 10" 
(8.3 cm x 25.4 cm) system
= 22.5 ft (6.8 m)
Install Vent System
1.  Place cardboard or similar material on top of a flat surface 
where you can easily assemble the downdraft vent system.
2.  Remove parts packages, downdraft vent, and blower box 
from the carton.
3.  Remove all shipping materials, tape, and film from the 
downdraft vent and blower box.
4.  Measure distance “X” from the cabinet floor to the top of  
the countertop. Subtract 28
1
/
2
" (72.4 cm) from distance “X” 
to determine dimension “Y” (X - 28
1
/
2
" = Y).
A
B
C
6 ft 
(1.8 m)
2 ft (0.6 m)
D
A.  Blower motor
B. Transition
C.  90° elbows
D.  Backdraft damper
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
downdraft vent.
Failure to do so can result in back or other injury.
Cabinet floor
Top of countertop
Downdraft vent
“X”
“Y”
  28¹⁄₂"
(73 cm)