Natural Gas Conversion
1.  Turn the manual shut-off valve to the closed position.
2.  Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1.  Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
2.  Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “LP” or “NAT” position. Turn over the spring 
retainer so the “NAT” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.
3.  Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure 
to the regulator should be as follows for operation and 
checking the regulator setting:
LP Gas:
Minimum pressure 6" (15.2 cm) WCP
Maximum pressure 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure 
shown on the model/serial/rating plate.
Line pressure testing above 
1
/
2
 psi gauge (14" WCP)
The cooktop and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 
1
/
2
 psi (3.5 kPa).
Line pressure testing at 
1
/
2
 psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than 
1
/
2
 psi (3.5 kPa).
To Convert Surface Burners
1.  If installed, remove the burner grates.
2.  Remove burner cap.
3.  Remove the burner base.
A
B
Large Dual Burner
A.  Burner cap
B.  Burner base
A
B
C
Medium Burner
A.  Burner cap
B.  Burner base
C.  Choke (for use with medium 
burner, LP gas only)
A
B
Small Burner
A.  Burner cap
B.  Burner base
4.  Apply masking tape to the end of a 7 mm nut driver to help 
hold the gas orifice spud in the nut driver while changing it. 
Insert nut driver into gas opening and press down onto the 
gas orifice spud and remove by turning the gas orifice spud 
counterclockwise and lifting out. Set gas orifice spud aside.
5.  Replace with correct Natural gas orifice spud. See the 
“Natural Gas Orifice Spud/Hood Chart.”
Use the following chart to find the exact orifice spud 
placement.
Remove choke from medium burner base.
Natural Gas Orifice Spud/Hood Chart
Burner 
Rating
Color
Size
Burner Style
5,000 BTUs
NG 5k 
Small 
Burner 
Bag
0.97 mm
Small burners
15,000 BTUs No color
1.75 mm
Medium burners
20,000 BTUs Blue/
Yellow
Black
1.98 mm
0.52 mm
Large burner - main 
Large burner - simmer
18,000 BTUs Red
1.93 mm
Grill burner 
(on some models)
Burner orifice spud
Grill orifice hood
A.  Size stamp or color
A.  Size stamp
A
B
C
A.  To cooktop
B.  Shut-off valve (closed position)
C.  Gas supply line
A
B
C
D
E
A.  Access cap
B. Gasket
C.  Gas pressure regulator
D.  NAT position
E.  LP position
A
A