Alternate Wiring
If wires will be connected to both R and Rc terminals, remove metal 
jumper.
Do not use C or X. Wrap bare end of wire with electrical tape.
If you have a heat pump without auxiliary/backup heat connect O or B
not both. If you do not have a heat pump, do not connect B. Wrap bare 
end of wire with electrical tape.
Place a jumper (piece of wire) between Y and W if you are using a heat 
pump without auxiliary/backup heat.
B       O       G       Y 
W
NOT
USED
R      Rc
M32734
4
4
7  Install Batteries
Install two AAA alkaline batteries.
Back of thermostat
RTHXXXX