Honeywell Bypass Drum Humidifier (HE120A) インストール手順

ページ / 48
HE120 BY-PASS DRUM HUMIDIFIER
11
69-1860EF—01
STEP 6: ASSEMBLE HUMIDIFIER
1.
Position the Bearing Bracket inside the Humidifier 
Housing to the side where the Bypass Duct is con-
nected. Make sure the “U” shape is pointing up. 
See Fig 20.
Fig. 20. Installing Bearing Bracket.
2.
Snap the Bearing Bracket into place.
3.
Position the Motor Plate on the opposite side of the 
Humidifier Housing with the wires at the bottom. 
See Fig 21.
Fig. 21. Installing Motor Plate.
4.
Snap Motor Plate into place.
5.
Place motor lead wires through bottom hole of Motor 
Cover and snap into place on outside of Humidifier. 
See Fig. 22.
Fig. 22. Installing Motor Cover.
6.
Install the Float Valve to the Humidifier Housing on the 
same side as the Motor Plate. See Fig. 24. (If the Float 
Valve is already installed on the same side as the Motor 
Plate, skip this step.)
a. Unscrew Float Valve Retaining Nut using a 1/2 in. 
wrench. See Fig. 23.
b. Remove Float Valve from housing.
c. Place Float Valve Stem through “D” hole on same 
side as the motor. See Fig. 24. (Float must be at 
bottom.)
d. Place Float Valve Washer over Float Valve Stem 
with recessed side of washer against the Humidifier 
wall. See Fig. 25.
e. Secure Float Valve using Float Valve Retaining Nut 
and tighten with 1/2 in. wrench. See Fig. 23.
IMPORTANT
The Float Valve must be installed on the same side 
of the Humidifier as the motor.
Fig. 23. Float Valve Retaining Nut.
SNAP TABS 
INTO PLACE
“U” SHAPE FACES UP
M13624
M13625
MOTOR WIRES AT BOTTOM
 M13610
VALVE SEAT
RETAINING NUT