Owner’s Guide 400-305-000-EFS
10
ENG
LISH
Press the main button for 3 seconds at any time (or do not press any button for 60 seconds) to save any changes you have
made and exit the setup menu.
Ventilation Mode
Select Units 
(US /Metric)
Set Fan Capacity 
(CFM or LPS)
ASHRAE 62.2
Pass/Fail
Set Floor Size 
(Sq. ft or Sq. M)
Set no. of 
Bedrooms
Press simultaneously
In Ventilation Mode, the controller sets the fan On/Off time to meet ASHRAE Standard 62.2 for
ventilation based on total floor space, number of bedrooms and fan capacity. In this mode, the
fan operates on a 60-minute cycle. For example, if the fan is On for 20 minutes, it will be Off for
40 minutes. To set the Ventilation Mode parameters, press the main button for 3 seconds to
display the setup menu and proceed as shown.
400-305-000-B (69-2316EFS-03).book  Page 10  Monday, September 28, 2009  11:06 AM