Ambient temperature 
and ventilation
Ambient temperature
The appliance is designed for a specific 
climate class. Depending on the climate 
class, the appliance can be operated at 
the following temperatures.
The climate class can be found on 
the rating plate. Fig. .
Note
The appliance is fully functional within 
the room temperature limits 
of the indicated climatic class. If 
an appliance of climatic class SN 
is operated at colder room temperatures, 
the appliance will not be damaged up to 
a temperature of +5 °C.
Ventilation
Fig. #
The air on the rear panel and on the side 
panels of the appliance heats up. 
Conduction of the heated air must 
not be obstructed. Otherwise, 
the refrigerating unit must work harder. 
This increases power consumption. 
Therefore: Never cover or block 
the ventilation openings!
Connecting 
the appliance
After installing the appliance, wait at least 
1 hour until the appliance is switched on. 
During transportation the oil in 
the compressor may have flowed into 
the refrigeration system.
Before switching on the appliance for 
the first time, clean the interior of 
the appliance (see chapter “Cleaning 
the appliance”).
Electrical connection
The socket must be near the appliance 
and also freely accessible following 
installation of the appliance. 
The appliance complies with the 
protection class I. Connect the appliance 
to 220–240 V/50 Hz alternating current 
via a correctly installed socket with 
protective conductor. The socket must 
be fused with a 10 to 16 A fuse.
For appliances operated in non-
European countries, check whether the 
stated voltage and current type match 
the values of your mains supply. This 
information can be found on the rating 
plate. Fig. . 
Warning
Never connect the appliance 
to electronic energy saver plugs.
Our appliances can be used with mains 
and sine-controlled inverters. Mains-
controlled inverters are used 
for photovoltaic systems which 
are connected directly to the national 
grid. Sine-controlled inverters must be 
used for isolated applications (e.g. on 
ships or in mountain lodges) which are 
not connected directly to the national 
grid.
Climate class
Permitted ambient 
temperature
SN
+10 °C to 32 °C
N
+16 °C to 32 °C
ST
+16 °C to 38 °C
T
+16 °C to 43 °C