Timberk SWH RE4 100 VH ユーザーズマニュアル

ページ / 28
10
10
8. MAINTENANCE
Fig. 9
Fig. 10
1. Check the power plug and outlet as often as possible. Secure electrical 
contact and also proper grounding must be provided. The plug and outlet 
must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with 
low  air  temperature  (below  0°C),  it  is  necessary  to  drain  water  from  the 
heater to prevent damage of the water heater (due to water freezing in the 
internal tank).
3. To  ensure  long  reliable  water heater  operation,  it  is  recommended  to 
regularly  clean  the  internal  tank  and  remove  deposits  on  the  electric 
heating  element  of  the  water  heater,  as  well  as  check  condition  (fully 
decomposed or not) of the magnesium anode and, if necessary, replace it 
with a new one in case of full decomposition.
4. Tank cleaning frequency depends on hardness of water located in this 
territory. Cleaning must be performed by special maintenance services. You 
can ask the seller for address of the nearest service center or find it on the 
website www.timberk.com. 
Preventive operations must be performed upon strict observance of the 
operation manual and safety precautions.
IMPORTANT!
The manufacturer provides an extended guarantee for particular 
water heater components provided that timely and proper routine 
maintenance is performed by specialists of an authorized service 
center (see the guarantee slip).
5. The water heater is equipped with a thermal  switch, which cuts off 
power  supply  of  the  heating  element  upon  water  overheating  or  its 
absence in the water heater. If the water heater is connected to the mains, 
but  water  is  not  heated  and  the  indicator  doesn't  light  up,  then  the 
thermal switch was switched off or not switched on. To reset the water 
heater to the operating condition, it is necessary to:
- de-energize the water heater, remove the plate of the side / lower cover. 
- press the button, located at the center of the thermal switch, Fig.10;
- if the button is not pressed and there is no clicking, then you should wait 
until the thermal switch cools down to the initial temperature.
6. Water can be drained through a composite relief valve (Fig. 9) (unscrew 
the composite relief valve drain knob screw and set the drain knob to the 
upper position, at that hot water tap must be open, and cold water supply 
valve must be closed).
IMPORTANT!
If these actions had no positive result or the thermal switch turns 
off repeatedly during a short period of time, then you should de-
energize the water heater, cut off water supply and contact your 
local Timberk Authorized Service Center for a consult or repair of 
the appliance.
IMPORTANT!
Never drain water if its temperature is over 50°C since it may result in 
burns.
Drain knob
Screw
Pressure relieving opening
www.timberk.com   electric storage water heater