2. G1/2 diameter pipes are used to connect the water heater to the water 
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets 
on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow 
of the water flow direction, so that the water flow direction coincides with 
direction of the arrow on the valve's case.
NOTE:
Do not mount additional accessories, such as a shut-off valve, between 
the relief valve and the inlet nozzle.
IMPORTANT!
If  water  in  the  installation  location  contains  a  large  amount  of 
calcium, manganese or iron salts, then IT IS NECESSARY to mount a 
respective filter in the delivery system to reduce the amount of scale 
generated in the tank and on the heating element.
Connection to electric main
IMPORTANT!
Prior to connecting the storage water heater, make sure that the 
water  heater  is  properly  grounded.  Proper  grounding  is 
important to minimize electric shocks and risk of fire. The power 
cord is equipped with a plug with a grounding pin. The appliance 
must  be  used  with  a  properly  grounded  power  outlet.  If  the 
outlet,  you  are  intending  to  use,  is  not  properly  grounded  or 
grounded  by  a  time-delay  fuse  or  a  circuit  breaker,  contact  a 
qualified electrician to install a proper outlet.
1. The water heater is designed to be connected to 220V single-phase 
electric  main. Prior  to connecting make sure that parameters of the 
electric  main  in  the  place  of  connection  correspond  to  parameters, 
specified on the identification plate with technical parameters of the 
appliance. You should follow the current electrical safety code when 
installing the water heater.
2. The power outlet must be properly grounded. The outlet must be 
designed for rated current not less than 10A, electric cable with copper 
core must have cross section not less than 3x1.5 mm2 (for copper).
The  power  outlet  and  plug  must  always  be  dry  to  prevent  current 
leakage. Regularly check if the power plug is tightly connected to the 
outlet.  Do  it  in  the  following  order:  insert  the  power  plug  into  the 
outlet, switch off the water heater after half-hour operation and unplug 
the cord, check if the plug is heated by your hand. If the plug is heated 
over 50°C, then to prevent damages, accidents and fire as a result of bad 
electrical contact, replace the outlet with a new one. A specialist must 
do this.
5. Water heater with the mounted valve must be connected to the water 
main   install a shut-off valve at the water inlet point. You need to connect a 
drain pipe to the opening of the pressure relief of safety valve. Next you 
should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle, 
marked red.
7. Open the shut-off tap and one of the tap assemblies. After the tank is 
filled with water, as evidenced by issue of water from the cock assembly, 
shut the cock assembly and check the leak integrity of all joints.
NOTE:
The  water  heater  is  an  appliance,  operating  in  such  a  manner  that 
pressure of water in the water heater corresponds to the pressure of 
water in water main. If pressure in the main exceeds 0.75 MPa, then it is 
necessary to mount a pressure reducer before the water heater so that 
pressure doesn't exceed 0.75 MPa.
www.timberk.com   electric storage water heater