Timberk SWH SE1 30 VO ユーザーズマニュアル

ページ / 24
Water heater mounting
NOTE:
To  install  the  water  heater,  please,  use  accessories  provided  by  the 
manufacturer. Electric water heater must not be mounted onto the wall 
before you make sure that the mounting strip is installed firmly and 
securely. Otherwise, the electric water heater may fall down from the 
wall  that  may  cause  its  damage  and  even  more  serious  accidents 
involving harm to health and personal injuries.
1.  After you have chosen a proper place to install the water heater 
determine points for holes for fixing of mounting strip, putting the strip 
to a wall. Drill holes of corresponding depth in the wall using a drill 
dimensionally fit for anchor bolts delivered together with the water 
heater. Next, fix the mounting strip on a wall with help of screws. After 
that you should mount water heater on a mounting strip (fig. 7).
2.  Fasten an AC main socket to the wall. Requirements to the socket are 
as follows: 220V / 10 , single-phase, three wires. It is recommended to 
place the socket from the right side higher of the water heater.
NOTE:
In the places accessible for water the AC electrical main socket must be 
installed on a height of at least 1.8 m from the ground.
Fig. 7
Connection to the water main
1. The water heater must be connected to the water main with 
minimum pressure of 0.1 MPa and maximum pressure of 0.7 MPa.
NOTE:
The  water  heater  is  the  appliance  operating  in  such  a  manner  that 
pressure of water in the water heater corresponds to the pressure of 
water in the water main. If pressure in the water main exceeds 0.7 MPa 
then it is necessary to install a pressure reducer before the water heater 
so that pressure will not exceed 0.7 MPa.
2.  To  connect  the  water  heater  to  the  water  main  apply  pipes  with 
diameter of G1/2.
3. To prevent water leakage when connecting pipes use rubber sealing 
gaskets on the threaded pipe ends.
4. Screw the safety pressure valve onto the inlet nozzle marked with blue 
colour and an arrow pointed water flow direction so that the water flow 
direction coincides with direction of the arrow on the valve case.
NOTE:
Do not install additional accessories, such as a cut-off valve, between 
the safety pressure valve and inlet nozzle.
5. Water heater with the mounted valve must be connected to the water 
main   install a shut-off valve at the water inlet point. You need to connect 
a drain pipe to the opening of the pressure relief of safety valve. Next you 
should put a drain pipe to the sewer.
6. Connect a desired number of consumption points to the outlet nozzle 
marked with red colour.
7. Check leak tightness of joints: open the cut-off valve and one of the 
outlet valves. After the tank is filled with water, as evidenced by outflow of 
water  from  the  outlet  valve,  turn  off  the  outlet  valve  and  check  leak 
tightness of all the joints.
6
www.timberk.com   electric storage water heater