Cisco Cisco ONS 15305 Multiservice Customer Access Platform トラブルシューティングガイド

ページ / 3
Inventory Failure on Cisco ONS 15305 − AC 230V
Module Installation
Document ID: 60564
Contents
Introduction
 Prerequisites
      Requirements
      Components Used
      Conventions
 Background Information
 Problem
 Solution
 Related Information
Introduction
This document describes one of the reasons why the Cisco ONS 15305 can generate an inventory failure
error message, and provides the solution.
Prerequisites
Requirements
Cisco recommends that you have knowledge of these topics:
Cisco ONS 15305
• 
Cisco Edge Craft
• 
Components Used
The information in this document is based on these software and hardware versions:
Cisco ONS 15305 Software Release 1.1.0
• 
Cisco Edge Craft Software Release 1.1
• 
The information in this document was created from the devices in a specific lab environment. All of the
devices used in this document started with a cleared (default) configuration. If your network is live, make sure
that you understand the potential impact of any command.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Background Information
A bank is a memory location in Cisco ONS 15305 where software and firmware are stored.