Technical Information 
Reverse Cable Equalizer Charts 
42 MHz and 40 MHz Reverse Cable Equalizer Loss Chart 
The following table shows the 42 MHz reverse cable equalizer loss. 
Note: The 42 MHz reverse equalizer also works as a 40 MHz reverse equalizer in 
systems that use 5-40 MHz reverse amplifiers. 
 
EQ 
Value 
EQ 
Value 
Insertion Loss at (MHz) 
Total 
Tilt 
Total 
Tilt 
(dB) 42 
MHz 
(dB) 40 
MHz 
42 
40 
35 
30 
25 
20 
15 
10 
(5-42 
MHz) 
(5-40 
MHz) 
1.0 
1.0 
1.1 
1.1 
1.2 
1.3 
1.4 
1.5 
1.7 
0.7 
0.7 
1.0 
1.0 
1.1 
1.3 
1.4 
1.6 
1.8 
2.0 
2.3 
1.3 
1.3 
3.1 
0.9 
1.0 
1.2 
1.4 
1.6 
1.9 
2.2 
2.5 
3.0 
2.1 
2.0 
4.1 
0.9 
1.0 
1.3 
1.6 
1.9 
2.2 
2.6 
3.0 
3.6 
2.7 
2.6 
5.1 
0.9 
1.0 
1.3 
1.7 
2.1 
2.5 
3.0 
3.5 
4.3 
3.4 
3.3 
6.1 
0.9 
1.0 
1.4 
1.8 
2.3 
2.8 
3.4 
4.1 
4.9 
4.0 
3.9 
7.2 
0.8 
1.0 
1.5 
2.0 
2.5 
3.1 
3.8 
4.6 
5.6 
4.8 
4.6 
8.2 
0.8 
1.0 
1.5 
2.1 
2.7 
3.4 
4.2 
5.1 
6.2 
5.4 
5.2 
9.2 
0.8 
1.0 
1.6 
2.2 
2.9 
3.7 
4.6 
5.6 
6.9 
6.1 
5.9 
10.2 
10 
0.8 
1.0 
1.7 
2.4 
3.2 
4.0 
5.0 
6.1 
7.5 
6.7 
6.5 
11.3 
11 
0.7 
1.0 
1.7 
2.5 
3.4 
4.3 
5.4 
6.6 
8.2 
7.5 
7.2 
12.3 
12 
0.7 
1.0 
1.8 
2.7 
3.6 
4.6 
5.8 
7.1 
8.9 
8.2 
7.9 
 
98 
OL-31156-01