Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
Chapter 1    Introduction 
 
 
 
GainMaker Amplifier Characteristics 
GainMaker System Amplifier modules have the following characteristics. 
 
-20 dB test points, located electrically outside of the diplex filter, provide for 
testing of forward output signals and reverse input signals without disrupting 
normal operation 
 
Backward compatibility with System Amplifier II and System Amplifier III 
housing bottoms provide reduced upgrade costs 
 
Housing lids offered with or without external test point 
 
Room for optional status monitoring transponder in housing lid 
 
Direct module plug-in to the housing provides superior amplifier heat sinking 
 
Symmetrical housing and modules provide convenient mounting 
-
 
Reversible amplifier module due to diagonally positioned input and main 
output ports, enabling installation of street-side housing lid access 
 
AC circuitry provides 15 A of steady state current capability that is able to 
withstand 25 A of peak current (for a maximum of 2 hours) 
 
Surge-resistant circuitry provides improved resistance to high voltage transients 
 
Chromated housing protects outdoor equipment in coastal areas and other 
corrosive environments; non-chromated housing also available 
 
Input and output reverse pad locations increase flexibility in reverse path design 
and alignment 
This amplifier can also be set up to operate at 870 MHz by using 870 MHz equalizers. 
The 870 MHz equalizers are listed together with the 1 GHz equalizers in Accessories 
(on page 7). 
 
Power Supply 
The DC power supply has the following features. 
 
Located in housing lid for ease of maintenance 
 
AC and DC test points provided on the power supply 
 
Selectable AC undervoltage lockout feature 
-
 
The 30 volt lockout is for 60 volt systems (factory default) 
-
 
The 40 and 50 volt lockout positions are for 90 volt systems (field configurable 
by moving a jumper) 
 
 
OL-31156-01