Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
 
Before You Begin 
Fastener 
Torque Specification 
Illustration 
Housing closure bolts 
5 ft-lb to 12 ft-lb 
(6.8 Nm to 16.3 Nm) 
 
Housing plugs 
Test point port plugs 
5 ft-lb to 8 ft-lb 
(6.8 Nm to 10.8 Nm) 
 
Module securing screws 
(Tx, Rx, PS, SM/LCM modules) 
25 in-lb to 30 in-lb 
(2.8 Nm to 3.4 Nm) 
 
RF cable connector 
20 ft-lb to 25 ft-lb 
(27.1 Nm to 33.9 Nm) 
 
Fiber optic cable connector 
20 ft-lb to 25 ft-lb 
(27.1 Nm to 33.9 Nm) 
 
 
Amplifier Module Cover 
GainMaker System Amplifier modules have aluminum cover attached to the chassis 
with self-tapping screws. Normal field maintenance will not require the removal of 
this cover. 
 
Module and Housing Compatibility 
Housing Lid 
The GainMaker System Amplifier module is compatible with the GainMaker housing 
lid only. The amplifier will not work with System Amplifier II, II+, or III housing lids. 
Housing Base 
The GainMaker System Amplifier module is compatible with the GainMaker housing 
base. The amplifier will also work with System Amplifier II, II+, and III housing 
bases. 
Important: GainMaker System Amplifier modules are marked with a blue label to 
indicate 15-ampere capability. The RF connectors in these modules are also marked 
with blue. These amplifier modules must be used in conjunction with a 15-ampere 
capable housing base, which again is marked with a blue label. 
Note: 15-ampere capable System Amplifier III housings with the blue label and 
System Amplifier II or II+ housings that have been upgraded to 15-ampere capability 
with an available seizure upgrade kit are compatible with GainMaker System 
Amplifier modules. 
 
 
OL-31156-01 
17