Chapter 3    Balancing and Setup 
 
 
 
The following diagram shows the location of the AGC related switch, controls, and 
AGC pad. 
 
 
To Select the AGC Pad Value 
1  
Use one of the following formulas to determine the correct AGC pad value. 
 
High Gain Dual, Low Gain Dual, and Balanced Triple: AGC pad value = RF 
output level at pilot frequency (main output port) - 34 dB 
 
Unbalanced Triple: AGC pad value = RF output level at pilot frequency (main 
output port) - 26 dB 
2  After finding the correct AGC pad value, install it in the amplifier in the AGC pad 
slot. The AGC setup illustration above also shows the location of the AGC pad. 
3  Proceed to To Align the AGC Module
 
To Align the AGC Module 
Complete the following steps to align the AGC module. 
 
62 
OL-31156-01