No AC Power 
No AC Power 
AC power can be measured at the amplifier seizure screws, AC shunt power 
directors, amplifier module test points, power supply harness, and AC test points. 
The following diagram illustrates the AC test point locations for the GainMaker 
System Amplifier. 
 
 
No AC Power Troubleshooting Table 
Before you begin troubleshooting for no AC power, verify that there is proper AC 
power input coming into the amplifier and that the AC voltage lockout threshold is 
set to your system's power requirements. 
Possible cause 
Solution 
No AC at the housing seizure. 
 
Check the AC source. 
 
Check the AC shunt power director 
configuration at the amplifier feeding AC to 
this amplifier. 
Note: Also verify the AC shunt power director 
configuration for AC output at this amplifier. 
 
Make sure that the housing seizure is properly 
tightened. 
 
OL-31156-01 