Cisco Cisco C880 M4 Server インストールガイド

ページ / 25
 
 
1.3 
Installation Specifications 
This section explains installation specification of each model. 
 
1.3.1  Installation Specifications 
TABLE 1.2 Installation Specifications 
Items 
Contents 
Cisco C880 
Server (E7-8800 
v2 CPU) 
Cisco C880 
Server (E7-8800 
v3 CPU) 
Dimensions  
[mm (in.)] 
Width 
445(17.52) 
Depth (*1) 
782(30.79) 
Length 
438(17.25) 10U 
Mass [kg (lb)] (*2) 
143(315) 
Conditions for air 
conditioner 
Max. calorific 
value 
[kJ/h (BTU/h)] 
Interruptible power source 
21,600(20,500)  
19,872(18,835) 
High efficiency power supply (*13) 
20,900(19,800) 
19.224(18,221) 
Displacement 
[m3/min (ft
3
/min)] 
(*3) 
Recommended environmental 
temperature 
12(424) 
Max. 
28(989) 
Temperature 
and Humidity 
conditions (*4) 
At the time 
of operation 
Temperature [°C (°F)]] 
(*5) 
Humidity [%RH] 
20 to 80 
Max wet bulb 
temperature [°C (°F)]] 
29 (84.2) 
Downtime 
(*6) 
Temperature [°C (°F)]] 
0 to 50 (32 to 122) 
Humidity [%RH] 
8 to 80 
Max wet bulb 
temperature [°C (°F)]] 
29 (84.2) 
Noise [dB] (*7, *8) 
60 
Acoustic power level [B] (*8) 
7.8 
Permissible 
Vibration [m/s
2
 
(gal)] 
At the time of operation (Including 
standby) 
4.0 (400) (Composite seismic wave) 
Downtime (*9) 
10.0 (1000) (Composite seismic wave) 
Permissible dust level [mg/m
3
0.15 
Power supply 
conditions 
Input voltage and source resultant pulse number 
200 to 240 VAC±10 % 
1φ 
Frequency and fluctuating Range 
50/60 Hz + 2/-4% 
Max power 
consumption / 
apparent power 
At the time 
of operation 
Interruptible power 
source (*13) 
6.00 kW/6.19 kVA 
5.52 kW/5.69kVA 
High efficiency power 
supply (*13) 
5.81 kW/5.99 kVA 
5.34 kW/5.51kVA 
Downtime 
0.084 kW 
Power factor (*10) 
0.95 or more 
Inrush current [A] [Rush hours] (*11) 
20 or less 
Leak current [mA] (*12) 
6.9 or less 
 
*1: Dimensions without protrusions 
*2: Numeric value when each optional device is mounted for maximum number of options. 
However, rail for mounting rack (5.7kg) and cable type are not included. 
Mass as per the installation configuration can be calculated using formula as shown below. 
Device mass = 77 + (9.6 * A) + (2.5 * B) + (1.8 * C) + (3.3 * D) [kg] 
A = Number of mounted SB (Minimum 1 to Maximum 4) 
B= Number of mounted IOU (Minimum 1 to Maximum 4) 
C= Number of mounted PSU (Minimum 2 to Maximum 6) 
D= Number of mounted DU (Minimum 0 to Maximum 2) 
*3: There are cases when device is overloaded or when abnormality is detected, FAN rotates at high-speed 
even if recommended environmental temperature is used.