8 Adding a PSU
This chapter describes the procedure for adding a high-efficiency PSU (200V), a PSU (200V).
Need to prepare power supply cables which match input AC cables.
See Table 9 and confirm the power supply configuration. The power supply configuration depends on
the total number of power supply units in the main unit including the PSU added.
Table 9
Prepared Power Supply Unit
PSU Configuration
Product Name
Qty.
High-efficiency Power Supply Unit (200V)
3
200V
Non-redundant power supply
4
200V
Redundant power supply
6
200V
Dual power feed
Power Supply Unit(200V)
3
200V
Non-redundant power supply
4
200V
Redundant power supply
6
200V
Dual power feed
SET0801000
8.1 Conditions for Adding Components
SET0801010
8.1.1 Number of mounted PSUs
A maximum of six PSUs can be mounted in the main unit.
SET0801020
8.1.2 Conditions concerning mixing different types of PSUs