3.1Switches on the Front Side 
12                                                          Operating  Manual                                                                                                             
 
 
3.1.  Switches on the Front Side 
There are three switches on the front side. They are available after taking off the  bezel only and should not 
be used by the customer. 
DC-ON switch (pushbutton) / AutoPower / MODE_SEL 
The switches should not be used by the customer (they are behind the  bezel). In the default 
settings, the storage subsystem powers ON/OFF  automatically with the data host. 
 
Default 
setting 
Operation 
MODE_SEL 
Off=down 
On=Up 
AutoPower 
Off=down 
On=up 
Yes
 
Power ON: SAS signal detected 
Power OFF: SAS signal not detected
 
ON
 
OFF
 
No*
 
Power ON: AC-ON and SAS signal d etected 
Power OFF: AC-OFF 
ON 
ON 
No* 
Power ON: DC-ON Switch 
Power OFF: DC-ON Switch for more than  4 sec 
and SAS signal not detected 
OFF 
OFF 
No* 
Power ON: AC-ON 
Power OFF: AC-OFF or DC-ON Switch  for 
more than 4 sec" 
OFF 
ON 
*: for service personnel and error diagnostics only 
 
3.2.  Indicator Elements on the Front Side 
You can see the following on the front side of the storage subsystem: 
– 
the four operating status LEDs which indicate the power supply, the ready  status, the fault status and 
the identification. The fifth LED (CACHE LED) is  covered by the bezel. 
– 
Status LEDs of the hard disk drives 
 
There is a Ready LED and a Fault LED for each of the 24 possible  hard disk drives.