5.Hard Disk Drives 
                                                                                                                                                                                25 
 
 
5.3.  Hot-Plug for Hard Disk Drives 
 
CAUTION! 
Before replacing an hard disk drive: To ensure the replacing of the correct  hard disk drive, switch on 
the blinking of the amber Fault LED (
section 
 on page 14
) of the 
depending hard  disk drive by ServerView RAID. 
If you want to replace an SAS hard disk drive during operation, proceed as  follows: 
If you want to pull out a hard disk drive which is not defective, you must 
ensure that no reading or writing access to this hard disk drive is possible. 
 
Pull the hard disk drive (defective/not defective) out by a few centimeters. 
 
Wait for at least 60 seconds. 
This period is necessary for the Host Bus Adapter to recognize that a hard disk drive has been 
pulled out and for the hard disk drive to  come to a stop. 
Pull the hard disk drive right out. 
Insert the new hard disk drive. 
When you have removed the hard disk drive and are not fitting any replacement,  then fit a blank insert into 
the blank bay. Ensure that the blank insert engages in  the bay correctly.