Cisco Cisco C880 M4 Server インストールガイド
4.Replacing Components
17
4.4. Replacing the Backplane
This component is NOT hot replaceable.
Requirements
–
The connected server has been shut down, and the server and the storage subsystem are switched off.
–
The power cables have been unplugged.
–
All other cables connected to the storage subsystem have been removed.
–
All HDD modules and dummy modules have been removed (as described in the operating manual).
–
The LED display has been removed (see section “Replacing the LED Display” on page 19).
–
The power supply units have been removed (as described in the operating manual).
–
The SAS expander module and the dummy blind righ
t beside it have been removed (see section “Replacing
–
The storage subsystem has been removed from the rack cabinet (see operating manual).
Figure 6: Screws securing the backplane case on the chassis
Remove the screws (flat-head Phillips screws) securing the backplane case.
Remove the backplane case and deposit it bottom up.
Backplane
Backplane case
Hard disk drives