Integral INSSD128GP25MXZ ユーザーズマニュアル
21
3.4 Power Management
System Power Consumption:
(Ta = 0 to 70
0
C)
Symbol Parameter
Conditions MIN
TYP MAX
Unit
Iccr
Read current
5V
-
130
-
mA
Iccw
Write current
5V
-
140
-
mA
Ipd
Power down current
5V
-
0.2
0.4
mA
Iccr
Read current
3.3V
-
200
-
mA
Iccw
Write current
3.3V
-
210
-
mA
Ipd
Power down current
3.3V
-
0.3
-
mA
4.0 Software Interface
4.1 ATA Task File Registers
The I/O decoding of each register is as follows
-CS1 -CS0 A2 A1 A0 -DIOR=0(-DIOW=1)
-DIOW=0(-DIOR=1)
1
0
0
0
0
Data(Read)
Data(Write)
1
0
0
0
1
Error
Feature
1
0
0
1
0
Sector Count
Sector Count
1
0
0
1
1
Sector Number (LBA7-0) Sector Number
(LBA7-0)
1
0
1
0
0
Cylinder Low (LBA 15-8) Cylinder Low (LBA
15-8)
1
0
1
0
1
Cylinder High (LBA
23-16)
Cylinder High(LBA
23-16)
1
0
1
1
0
Drive/Head (LBA 27-24)
Drive/Head (LBA 27-24)
1
0
1
1
1
Status
Command
0
1
1
1
0
Alternate Status
Device Control
0
1
1
1
1
Drive Address
Reserved