Cisco Cisco Unified MeetingPlace 8.5 クイック設定ガイド
Using Alarms and Logs on Cisco Unified MeetingPlace
Viewing the System Log
9
SIM UP "07/11/08 18:32 Rel_7_1_0_67"
DBSERVER UP "07/11/08 18:18 Rel_7_1_0_67"
SNMPD UP "07/11/08 18:32 Rel_7_1_0_67"
CPSERVER UP "07/11/08 18:31 Rel_7_1_0_67"
POSERVER UP "07/11/08 18:19 Rel_7_1_0_67"
CONFSCHED UP "07/11/08 18:26 Rel_7_1_0_67"
TRIGGER_WATCH UP "07/11/08 18:33 Rel_7_1_0_67"
POCLIENT UP "07/11/08 18:39 Rel_7_1_0_67"
GWSIMMGR UP "07/11/08 18:33 Rel_7_1_0_67"
VOICESERVER UP "07/11/08 18:30 Rel_7_1_0_67"
NMPAGENT UP "07/11/08 18:32 Rel_7_1_0_67"
CHECKLIC UTIL DONE "07/11/08 18:35 Rel_7_1_0_67"
Related Topics
•
module
•
Alarm and Exception Code Reference for Cisco Unified MeetingPlace at
•
Viewing the System Log
The system log captures and buffers high-level details about system software activities. You can choose
the severity level that you want to see. The output lists the date and time of the exception, the exception
code, the file in which the exception occurs, and a text description of the exception.
the severity level that you want to see. The output lists the date and time of the exception, the exception
code, the file in which the exception occurs, and a text description of the exception.
Note
The system sorts messages by using the date and time that each message was added to the log file. If
time is not synchronized across all Cisco Unified MeetingPlace servers, then the time used for sorting
may differ from the displayed time stamps, and the log messages may seem to appear out of order. The
system uses the time stamp for each message to filter out messages that are outside the specified start
and end dates.
time is not synchronized across all Cisco Unified MeetingPlace servers, then the time used for sorting
may differ from the displayed time stamps, and the log messages may seem to appear out of order. The
system uses the time stamp for each message to filter out messages that are outside the specified start
and end dates.
Procedure
Step 1
Log in to the Administration Center.
Step 2
Click Services > Logs > View System Logs.
Step 3
Configure the fields.
Step 4
Click View Logs.
Related Topics
•
in the
module
•
in the
module
•
Alarm and Exception Code Reference for Cisco Unified MeetingPlace at