STEP 11
ORDER POWER SUPPLY
The C240 M4 server requires at least one power supply. A lightly loaded server may require one 
or two 650 W power supplies. A fully loaded server might need to be powered with two larger 
capacity power supplies. A server with one GPU requires at least two power supplies (1400 W 
power supplies are recommended). A server with two GPUs also requires at least two power 
supplies (1400 W power supplies are recommended). Use the power calculator at the following 
link to determine the needed power based on the options chosen (CPUs, drives, memory, and so 
on):
Table 22
   Power Supply 
Product ID (PID)
PID Description
UCSC-PSU2V2-1400W 
1400 W V2 AC Power Supply (200 - 240V) 2U & 4U C Series
UCSC-PSU2V2-1200W
1
Notes . . .
1. The power output is 1200W with a 200-240V input and 800W with a 100-120V input.
1200 W / 800W V2 AC Power Supply for 2U C-Series Servers
UCSC-PSU-930WDC
930 W -48V DC Common Slot Power Supply for C-series servers 
UCSC-PSU2V2-930DC
930 W - 48V V2 DC Power Supply for 2U C-Series Servers
UCSC-PSU2V2-650W
650W V2 AC Power Supply for C-Series Servers
NOTE:  In a two power supply server, both power supplies must be identical.