Known limitations 
Cisco TelePresence System C-Series Software Release Notes  
Page 25 of 36 
 
 
 
* Open the Services Control Panel (Control 
Panel->Administrative Tools ->Services) 
 
* For each service in the list below, select the 
service from the Services list, and use the 
restart icon or right-click->restart to restart the 
service 
 
-  World Wide Web Publishing Service 
 
-  TMSDatabaseScannerService 
 
-  TMSLiveService 
 
-  TMSSchedulerService 
 
-  TMSSNMPService 
 
* Log into the TMS  Web Interface, browse to 
the system and do a ‘Force Refresh’.  TMS 
should communicate to the system properly and 
the error message will clear. 
* To minimize service abruption it will be 
beneficial to upgrade all systems in one go, 
avoiding following the above procedure for 
every  endpoints you upgrade. A future TMS 
version will resolve this condition negating the 
need to restart the services. 
 
Workaround to restore the release keys: 
* Once TMS  has restored communication with 
the systems, upgrade the units one more time. 
This time TMS  will be able to communicate with 
the systems when they boot up and set the 
release keys.  
 
Note:  Please read the resolved caveats 
section Reference ID 85930 as well. 
 
Note:  The above issues are fixed for TMS 
13.0 
CSCtr32348 
TANDBERG PrecisionHD 1080p Camera 
all SW versions. 
720p50, 720p30 and 720p25 output has no 
CRC included for HD-SDI. Depending on the 
device you connect the camera to, you may not 
get video using this format. The Cisco C-Series 
codecs will support these formats. 
N/A 
Ver. TC2.1.0 and above 
Startup scripts will not work with Windows end 
of line. You must use Unix end of line to be able 
to run multiple commands. Most editors have 
the option to set which format to use. If you use 
Notepad ++, you can set Unix format in the 
Settings/Preferences menu.  
N/A 
Ver. Any 
If you run cascaded cameras and the chained 
cameras are running an old camera code, we 
have seen that only zoom works when trying to 
control the chained camera. The solution is to 
connect the cascaded camera as the first 
camera in the chain so that the camera is 
detected and upgraded by the codec, or use the 
Ethernet upgrade method. 
N/A 
Ver. Any 
HD-SDI may not work with cables shorter than