Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch

ページ / 5
2
Release Notes for Cisco Small Business 200E Series Advanced Smart Switches Release 1.0.6.2
Release Notes
Limitations and Restrictions
The following caveats are acknowledged in release 1.0.6.2:
Problem:
LLDP-MED (applicable to PoE devices) is not fully operational. 
Connected devices only show the Remote ID and Remote Port ID.
Solution:
Use CDP, however, LLDP-MED specific data will not be visible.
Problem:
Changing Spanning-Tree Mode from RSTP to MSTP will not take effect 
immediately upon saving the configuration.
Solution:
Reboot the switch.
Problem:
You cannot change the active link for STP and RSTP by changing the 
Port Path Cost.
Solution:
Use the External Port Path Cost to change it. Note that this method is 
only intended for MSTP, however, it may be used for STP and RSTP until an official 
release to correct it has been released.
Problem:
The configured time settings will not be preserved upon a reboot, 
regardless of the method used to set them.
Solution:
Manually reset the time upon reboot.
Problem:
It may take up to 5 minutes for Bonjour to detect the switch after a 
reboot.
Solution:
There is no workaround.
The following limitations are carried over from Release 
1.0.5.1
Problem:
With a configuring PC attached to port g1, the MAC address binds to 
the port. After disconnecting from the switch, the PC can still connect to the switch 
and manage the DUT on other ports if using the same MAC address.
Solution:
There is no workaround.
Problem:
When using Internet Explorer version 6 the Filter label is displayed 
vertically.
Solution:
Use Internet Explorer version 8 or a different browser.